• 2805-2020

    Plate Heat Exchangers Not Meeting Performance

    The Plate Heat Exchanger is relatively new heat transfer technology and they perform very well due to the research and design that is behind them. Plate and Frames are inexpensive, highly efficient and unlike other types of heat transfer equipment, they are modifiable after any length of performance. Their design is able to be adjusted to fit the ideal size for the current process, and the current process is often not what it used to be.

  • 2605-2020

    The Glued Heat Exchangers Gasket Conundrum

    You walk past one of your plate heat exchangers that's been working great for a long time. But, today you notice that it''s leaking onto the floor in several different locations. You need this heat exchanger for a critical heating or cooling application at your facility. You can''t remember ever changing the gaskets on the unit, so you run to your office to get the records on the heat exchanger. You notice that the unit was supplied with glued gaskets.....what now?

  • 2005-2020

    Plate Heat Exchangers: External Leakage

    Plate heat exchangers can supply reliable operating service for years with proper maintenance, but what about when something goes wrong? Is your plate heat exchanger leaking? Is the leak slow or fast? How can you know what the problem is and the best way to address it. We'll review some of the basics to help you troubleshoot problems with gaskets or the maintenance condition of your plate exchanger.

  • 1405-2020

    Integrated Heat Transfer Products

    Centralized heating is an important symbol of urban modernization, as well as an important measure to save energy and improve the environment. With the continuous development of the heating industry, the majority of users have expressed higher requirements for the stability and quality of heating. Plate heat exchanger unit is the principal part of heat exchange station. The New Roc Industrial Limited series plate heat exchange unit was developed according to the characteristics of centralized heating. The unit has good environmental protection performance, the overall running noise is lower than 70db, the structure is compact, the appearance is beautiful, and the operation is convenient, safe and reliable.

  • 0305-2020

    Types of Plate Exchanger Leaks

    The design of plate heat exchangers is very reliable since they have several fail-safe spots to visibly show any leaks.  Nearly all possible leaks will cause the flow to spill out the sides of the exchanger to the ground so the problem becomes obvious.

  • 2704-2020

    Plate Heat Exchanger As Vaporizer and Condenser-3

    Plate heat exchangers (PHEs) have been installed in larger heat pump systems and refrigeration systems since the 1980s. Tech-nicians who deal with these systems need to know some specific details of how they work. Part one of this article covered PHE design, on-site assembly and service, leak indication, freezing risk, and resistance from vibration, pressure, and seismic occurrences. This week the article continues its discussions of the plate heat exchanger as vaporizer and condenser.

  • 2404-2020

    Plate Heat Exchanger As Vaporizer and Condenser-2

    Plate heat exchangers (PHEs) have been installed in larger heat pump systems and refrigeration systems since the 1980s. Tech-nicians who deal with these systems need to know some specific details of how they work.Part one of this article covered PHE design, on-site assembly and service, leak indication, freezing risk, and resistance from vibration, pressure, and seismic occurrences. This week the article continues its discussions of the plate heat exchanger as vaporizer and condenser.

  • 2004-2020

    Plate Heat Exchanger As Vaporizer and Condenser-1

    Plate heat exchangers (PHEs) have been installed in larger heat pump systems and refrigeration systems since the 1980s. Tech-nicians who deal with these systems need to know some specific details of how they work.Part one of this article covered PHE design, on-site assembly and service, leak indication, freezing risk, and resistance from vibration, pressure, and seismic occurrences. This week the article continues its discussions of the plate heat exchanger as vaporizer and condenser.

  • 1803-2020

    How to perform a physical examination on the heat exchanger station-circulating pump

    Physical examination on the heat exchange station is much simpler than that on human beings, the examination items are no more than temperature, flow, pressure, power and several key points, through these simple parameters, 3 important indicators of heat rate, power consumption and pressure drop were examined, so as to find the crux of the problem of “three highs” of the heat exchange station. Let us see the high-end customized health care services that heating stations can enjoy: